HPE_a00088902en_us_HPE Primera Red Hat Enterprise Linux and Oracle Linux Implementation Guide.pdf
186
86页
3次
2023-05-05
免费下载
HPE Primera Red Hat Enterprise Linux Implementation
Guide
Part Number: 20-PRI600-RHIG-ED4
Published: October 2021
Edition: 4
Abstract
This guide provides instructions for establishing communication between an HPE Primera storage system and a host
running Red Hat Enterprise Linux using the FC (Fibre Channel) and iSCSI (Internet Small Computer System interface)
protocols. It is intended for system and storage administrators who manage system configurations and resource allocation
for the HPE Primera storage system. Administrators must be very familiar with the host OS and the HPE Primera storage
system. For predictable performance and results, use the information in this guide with documentation provided by HPE
for the HPE storage system and documentation provided by individual product vendors.
©
Copyright 2019, 2021 Hewlett Packard Enterprise Development LP
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise
products and services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable
for technical or editorial errors or omissions contained herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or copying.
Consistent with FAR 12211 and 12212, Commercial Computer Software, Computer Software Documentation, and
Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard Enterprise has no
control over and is not responsible for information outside the Hewlett Packard Enterprise website.
Acknowledgments
Intel
®
, Itanium
®
, Optane
, Pentium
®
, Xeon
®
, Intel Inside
®
, and the Intel Inside logo are trademarks of Intel Corporation
or its subsidiaries.
AMD and the AMD EPYC
and combinations thereof are trademarks of Advanced Micro Devices, Inc.
Microsoft
®
and Windows
®
are either registered trademarks or trademarks of Microsoft Corporation in the United States
and/or other countries.
Adobe
®
and Acrobat
®
are trademarks of Adobe Systems Incorporated.
Java
®
and Oracle
®
are registered trademarks of Oracle and/or its ailiates.
UNIX
®
is a registered trademark of The Open Group.
All third-party marks are property of their respective owners.
Revision history
Part number
Publication
date
Edition Summary of changes
20-PRI600-RHIG-ED4 October
2021
4 Updated the "HPE Primera Persistent Ports—iSCSI
connectivity guidelines" section.
P23952-003 May 2021 3 Updated the maximum number of I/O paths recommended
and tested by Hewlett Packard Enterprise.
In “Creating the HPE Primera virtual volumes” topic, added
statement that presenting same virtual volume across
dierent protocols is not supported.
P23952-002 June 2020 2 Added iSCSI support.
P23952-001 September
2019
1 Initial release for HPE Primera storage systems.
Contents
Introduction to the HPE Primera Red Hat Enterprise Linux Implementation
Guide.................................................................................................................................... 6
Linux host requirements..............................................................................................................................................................................................6
Supported features.........................................................................................................................................................................................................6
HPE Primera All Flash Arrays..................................................................................................................................................................6
HPE Peer Persistence.................................................................................................................................................................................. 6
HPE Persistent Checksum.........................................................................................................................................................................6
HPE Persistent Ports................................................................................................................................................................................... 7
HPE Smart SAN - FC.................................................................................................................................................................................... 7
HPE Primera documentation.................................................................................................................................................................................... 8
Accessing documentation on SPOCK.................................................................................................................................................8
FC protocol quick connect................................................................................................ 9
iSCSI protocol quick connect......................................................................................... 13
Connecting the storage system to the host using the FC protocol........................ 15
Target port limits and specifications—FC......................................................................................................................................................15
HPE Persistent Ports..................................................................................................................................................................................................16
HPE Persistent Ports setup and connectivity guidelines—FC......................................................................................... 16
HPE Smart SAN - FC...................................................................................................................................................................................................17
HPE Persistent Checksum—FC considerations.......................................................................................................................................... 17
Connecting the HPE Primera storage system to the host....................................................................................................................17
Setting up and zoning the fabric—FC.............................................................................................................................................18
FC switch configuration guidelines...................................................................................................................................................19
Configuring ports on the storage system.......................................................................................................................................................21
Configuring storage system ports for fabric or direct connections to the host.....................................................22
Configuring the host—FC........................................................................................................................................................................................ 23
Using the Emulex HBA.............................................................................................................................................................................23
Using the Marvell HBA.............................................................................................................................................................................24
(Optional) Enabling storage feature-specific host driver parameters ........................................................................28
HPE Persistent Checksum over FC...................................................................................................................................................30
Connecting the storage system to the host using the iSCSI protocol....................37
Planning the implementation.................................................................................................................................................................................37
Implementation workflow.......................................................................................................................................................................38
iSCSI target port limits and specifications....................................................................................................................................38
HPE Primera Persistent Ports—iSCSI connectivity guidelines.........................................................................................39
Connecting the host and the storage system to the fabric..................................................................................................................40
Enterprise iSCSI............................................................................................................................................................................................40
Configuring iSCSI ports on the storage system for IPv4.......................................................................................................................41
Configuring iSCSI ports on the storage system for IPv6 for VLAN tagging..............................................................................42
Configuring iSCSI software......................................................................................................................................................................................42
iSCSI drivers....................................................................................................................................................................................................42
3
of 86