How to Replace an Exadata_ZDLRA X7_X8_X9_ Storage Cell Server F640 Flash Card.pdf
24
8页
0次
2025-01-22
10墨值下载
Oracle System Handbook - ISO 8.5 April 2024 Internal/Partner Edition
Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback
Asset ID: 1-71-2362260.1
Update Date: 2023-10-11
Keywords:
Solution Type Technical Instruction Sure
Solution 2362260.1 : How to Replace an Exadata/ZDLRA X7/X8/X9/ Storage Cell Server F640 Flash Card
Related Items
Zero Data Loss Recovery Appliance RA23
Zero Data Loss Recovery Appliance RA21
Oracle SuperCluster M7 Hardware
Exadata Database Machine X8-8/X8M-8 Hardware
Exadata X7-2 Hardware
Exadata Database Machine X9M-2 Hardware
Zero Data Loss Recovery Appliance X8/X8M Hardware
Gen 2 Exadata Cloud at Customer X8-2/X8M-2 Hardware
Gen 2 Exadata Cloud at Customer X9M-2 Hardware
Zero Data Loss Recovery Appliance X7 Hardware
Exadata Database Machine X9M-8 Hardware
Oracle SuperCluster M8 Hardware
Exadata X7-8 Hardware
Exadata Database Machine X8-2/X8M-2 Hardware
Related Categories
PLA-Support>Sun Systems>x86>x86 Generic Prod>SN-x64: CAP VCAP
KB Review>KB Review.Reviewed-OK
PIW Review>PIW Review.Reviewed-Waiting on Product Change
CAP/VCAP>CV-CAP
In this Document
Goal
Solution
References
Applies to:
Zero Data Loss Recovery Appliance RA23 - Version All Versions and later
Zero Data Loss Recovery Appliance RA21 - Version All Versions and later
Zero Data Loss Recovery Appliance X7 Hardware - Version All Versions and later
Oracle SuperCluster M7 Hardware - Version All Versions and later
Exadata Database Machine X8-8/X8M-8 Hardware - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace an Exadata/ZDLRA X7/X8/X9/ Storage Cell Server F640 Flash Card
Solution
DISPATCH INSTRUCTIONS
Special Instructions for Dispatch are required for this part.
For Attention of Dispatcher:
The parts required in this action plan may be available as spares owned by the customer, which they received with the Engineered System. (These are sometimes referred to as ride-
along spares.)
If parts are not available to meet the customer preferred delivery time/planned end date, then request TAM or field manager to contact the customer, and ask if the customer has parts
available, and would be prepared to use them.
If customer spare parts are used, inform the customer that Oracle will replenish the customer part stock as soon as we can. More details on this process can be found in GDMR
procedure "Handling Where No Parts Available" step 2:
https://ptp.oraclecorp.com/pls/apex/f?p=151:138:38504529393::::DN,BRNID,DP,P138_DLID:2,86687,4,9082 ,
WHAT SKILLS DOES THE ENGINEER NEED: Exadata X10M Training
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 2
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: An Exadata/ZDLRA X7/X8/X9 Storage Cell Server Flash F680/F640v4 needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
IMPORTANT NOTE TO TSC ENGINEER: CUT & PASTE the “CUSTOMER ACTIVITY” sections of the Pre-Replacement and Post-Replacement steps into a SR Note and
ensure the customer is aware to do these steps prior to the scheduled field engineer activity, and during and after the replacement activity.
CUSTOMER ACTIVITY:
The Flash F640 Card is hot-pluggable in the Exadata X7/X8/X9/ Storage Cell Server and can be replaced with the system operating if steps are taken to prepare the card for
removal.